CLOVER Incinerators
 
China Ecological Incinerator Manufacturer
               

 

      Home Contact Us    




 



 

  嶄猟    Русский

 Tel:+8625-84610201
 Fax:+8625-84610406
 Website: www.clovermed.net
 Email:  info@hiclover.com

>Home

 >Contact Us

 Programmable Logic Controller

 Burning Rate&Model

 10kgs per hour/TS10 PLC

 20kgs per hour/TS10 PLC

 30kgs per hour/TS10 PLC

 50kgs per hour/TS10 PLC

 100kgs per hour/TS10 PLC 

>Containerized Incinerator

 Medical Waste Incinerators

30kgs per hour&Model YD-30

50kgs per hour&Model YD-50

100kgs per hour&Model YD-100

150kgs per hour&Model YD-150

300kgs per hour&Model YD-300

500kgs per hour&Model YD-500

 Incinerator Project Case

Incinerator YD-30 for Australia

Incinerator YD-50 for Moldova

Incinerator YD-100 for Iraq

Incinerator YD-150 for Morocco

Incinerator YD-300 for Somalia

Incinerator YD-500 for Vietnam

>Small Incinerator

>Large Incinerator

Burn Rate(Kgs/hour)

10kgs per hour Incinerator

20kgs per hour Incinerator

30kgs per hour Incinerator

50kgs per hour Incinerator

100kgs per hour Incinerator

150kgs per hour Incinerator

300kgs per hour Incinerator

500kgs per hour Incinerator

Pet Crematory 50kgs per hour New

Request Dealer

>Light Oil Burner

>Gas Burner

>Incinerator FAQ (PDF)

>How to Buy

>Photo Gallery 

>Certificate

>Burners

>Sterilization System

>What's New

>Company Brief(PDF)

 

 

 

 

 

 

 

Gas Fuel Burner

Burner Performance feature
Al-in-one blower.
Auto-operation
Manual switch for one stage/two stage
Gas auto-leakage(option)double solenoid valve (single vafive for one stage)
Protect for the gas pressure ensure to stop burner running when the gas pressure is too high or too low.
Protect for the air pressure ensure to stop burner running when the air pressure is too low.
Sweep the tube before ignition.
Safety flame monitors system.
The servo motor will close the air gate when stop the burner.(manual adjust the air gate for one stage)
The servo motor moves the camto control the air gate and the gas butterfly valve which adjusting the consumption of air and gas.(For modulating & Sliding series)
Convenient for the installation,commissioning and maintenance because the gemel connection between the burners body and tube
The burner is easy to install for the portable body,The client just connects the power supply and gas suply and gas supply then can start the burner.
The little running noise and the discharge gas can suitable for the demands of the environmental protection.
Can suitable different kind of fuel gas.
The standard collocate Electric protect grade is IP40.

Burner Operation

BT...GF On-off
BT...GRF HI-LOW with servo motor
BT...GS/M Sliding/Modulting with servo motor

 

Gas Burner - One-Stage Gas Burner - Modulating Gas Burner
 Model Output max.(Kw) Output min.(Kw)  Model Output max.(Kw) Output min.(Kw)
 BT3GF 41.9 16.3  BT17GS/M 168 50
 BT6GF 56.3 30.6  BT35GS/M 340 60
 BT11GF 99 48.8  BT40GS/M 425 185
 BT17GF 168 69  BT60GS/M 738 248
 BT20GF 200 50  BT100GS/M 995 280
 BT30GF 300 60  BT120GS/M 1200 350
 BT35GF 358 90  BT150GS/M 1428 414
 BT50GF 596 169  BT200GS/M 2000 490
 BT60GF 738 248  BT250GS/M 2500 590
Gas Burner - TWO-Stage  BT350GS/M 3500 924
 Model Output max.(Kw) Output min.(Kw)  BT400GS/M 3800 924
 BT17GRF 168 69  BT450GS/M 4000 550
 BT20GRF 200 50  BT550G S/M 5400 600
 BT30GRF 300 60  BT650G S/M 7400 800
 BT35GRF 358 90  BT1000G S/M 10500 1000
 BT40GRF 425 185 Gas Burner - Coal-gas-burner
 BT60GRF 738 248  Model Output max.(Kw) Output min.(Kw)
 BT100GRF 995 280  BT11TGF 109 48
 BT120GRF 1200 350  BT17TGF 150 69
 BT150GRF 1428 414  BT30TGF 208.8 101
 BT200GRF 2000 490  BT40TGF 320 186
 BT250GRF 2500 590  BT60TGF 465 184
 BT300GRF 2982 657  BT30TGF 208.8 101
 BT350GRF 3500 924  BT35TGF 279 128
 BT400GRF 3950 924  BT40TGF 320 186
Model Specification  BT60TGF 465 184
TC-10G OFF-ON, Output(10Kcal/H):1-2  BT100TGF 755 355
TC-30G OFF-ON, Output(10Kcal/H):3  BT150TGF 1451 653
GOM-2 OFF-ON, Output(10Kcal/H):12  BT250TGF 2362 715
GOM-3 OFF-ON, Output(10Kcal/H):20      
AG-100 Two stage, Output(10Kcal/H):80      

china Double chamber incinerator manufacturer

china animal cremator china animal waste incinerator china pet cremation equipment china small animal incinerator
china pet Crematoriums equipments incinerator animals concrete combustion chamber

          

*Home * YZ Incinerator * YD Incinerator * SYC Incinerator * CONVO Incinerator * Containerized Incinerator * Burner * Contact Us
*
10kgs per hour Incinerator * 20kgs per hour Incinerator * 30kgs per hour Incinerator * 50kgs per hour Incinerator *
*
100kgs per hour Incinerators * 150kgs per hour Incinerator * 300kgs per hour Incinerator * 500kgs per hour Incinerator *
Clover Medical Limited
Rm.411, 07 Building, East Wanda Plaza, 58# Yunjin Road, Nanjing, P.R.China Post Code: 210019
Tel: +86-25-84610201 Fax: +86-25-84610406
Website: www.clovermed.net Email: cloverincinerator@gmail.com